Myoview at a Glance

  • Rapid cardiac imaging 
    Myoview can begin to acquire diagnostic information in as soon as 15 minutes for stress MPI *1 
  • Potential for shorter throughput and fewer repeat scans.2
    Myoview demonstrated significantly shorter completion time for both rest studies and throughput time2
    Patients receiving Myoview required fewer repeat scans due to interference of extra cardiac activity2

  • Flexible one- or two-day protocols
    may help optimize department scheduling, as well as enable a  through-put improved workflow 

Kit reconstitution and image acquisition1

15-minute start time to image acquisition enables efficient protocol for stress and rest imaging

Supporting Materials

Customer Resources

Invested in the advancement of Nuclear Cardiology—both today and tomorrow

Contact Us

If you would like to order Myoview online, please visit our web ordering platform.

  1. Myoview [prescribing information]. Arlington Heights, IL: GE Healthcare; 2017. 
  2. Ravizzini GC, Hanson MW, Shaw LK, et al. Nucl Med Comm. 2002;23:203-208. Erratum in April 2006.

WARNINGS AND PRECAUTIONS

  • Risks Associated With Exercise or Pharmacologic Stress: Patients evaluated with exercise or pharmacologic stress may experience serious adverse reactions such as myocardial infarction, arrhythmia, hypotension, and bronchoconstriction, as well as cerebrovascular reactions such as headache, paraesthesias, convulsions, somnolence, and cerebrovascular accident, including hemorrhage. Perform stress testing in a setting where cardiac resuscitation equipment and trained staff are readily available. When pharmacologic stress is selected as an alternative to exercise, perform the procedure in accordance with the pharmacologic stress agent's Prescribing Information
  • Hypersensitivity Reactions: Hypersensitivity reactions, including anaphylaxis, dyspnea, bronchospasm, throat tightness, coughing, tachycardia, chest pain, hypotension, abdominal pain, and cutaneous reactions (rash, urticuria, pruritus, erythema, and swelling or angiodema) have been observed after the administration of Myoview. Always have cardiopulmonary resuscitation equipment and personnel available, and monitor all patients for hypersensitivity reactions

ADVERSE REACTIONS

  • Serious episodes of angina, ventricular tachycardia, and respiratory arrest were reported. Other events included angina, hypertension, torsades de pointes, vomiting, abdominal discomfort, cutaneous allergy, hypotension, dyspnea, metallic taste, burning of the mouth, and smell alteration. The following were reported when used with pharmacological stress: Angina, flushing, dyspnea, headache, abdominal pain, dizziness, palpitations, nausea, hypotension, pain, cough, arrhythmia, bronchospasm, ECG (electrocardiogram) abnormalities, hypertension, vomiting, and asthenia. Postmarketing adverse reactions included rash, urticaria, abnormal vision, hypersensitivity reactions, and fever

USE IN SPECIFIC POPULATIONS

  • Nursing Mothers: Technetium Tc-99m tetrofosmin is present in human milk in small amounts (<1% of maternal dose). There are no data available regarding the effects of technetium Tc-99m tetrofosmin on the breastfed infant or on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for Myoview and any other potential adverse effects on the breastfed child from Myoview or from the underlying maternal condition.  To decrease radiation exposure to the breastfed infant, advise a lactating woman to pump and discard for 60 hours (10 half-lives) after technetium Tc99m tetrofosmin administration.  
  • Pediatric Use: Safety and effectiveness in pediatric patients have not been established
  • Geriatric Use: No overall differences in safety were observed between these subjects and younger subjects. Other reported clinical experience has not identified differences in responses between elderly patients and younger patients, but greater sensitivity regarding some older individuals cannot be ruled out

PRODUCT INDICATIONS AND USE

Myoview™ 30 (Kit for the Preparation of Technetium Tc-99m Tetrofosmin for Injection) is indicated for myocardial perfusion imaging under rest and/or exercise or pharmacologic stress conditions to delineate regions of reversible myocardial ischemia or infarcted myocardium in patients with known or suspected coronary artery disease. Myoview is also indicated for the assessment of left ventricular function (left ventricular ejection fraction and wall motion) in patients with known or suspected heart disease.

JB01543IN

WIPRO GE HEALTHCARE PVT LTD
No. 4, Kadugodi Industrial Area,
Bangalore 560067,
Karnataka, India
CIN: U33111KA1990PTC01606